MBD-X11SSH-LN4F |
|
|
 |
Form Factor |
|
Dimensions |
- 9.6" x 9.6" (24.38cm x 24.38cm)
|
|
 |
CPU |
- Intel? 7th/6th Generation Core i3 series
- Intel? Celeron?
- Intel? Pentium?
- Intel? Xeon? Processor E3-1200 v6/v5 series
- Socket H4 (LGA 1151) supported; CPU TDP support 80W
|
Note |
- BIOS version 2.0 or above is required to support 7th Generation Intel? Core? i3 Processors and Intel? Xeon? Processor E3-1200 v6 series
|
|
 |
Memory Capacity |
- 64GB Unbuffered ECC UDIMM, DDR4-2400MHz, in 4 DIMM slots
|
Memory Type |
- 2400/2133/1866/1600MHz ECC DDR4 SDRAM 72-bit, 288-pin (UDIMM) gold-plated DIMMs
|
DIMM Sizes |
|
Memory Voltage |
|
Error Detection |
- Corrects single-bit errors
- Detects double-bit errors (using ECC memory)
|
|
 |
Chipset |
|
SATA |
- Intel? C236 controller for 8 SATA3 (6 Gbps) ports; RAID 0,1,5,10
|
Network Controllers |
- Quad Intel? Ethernet Controller I210-AT
|
Graphics |
|
|
 |
USB |
- 6 USB 2.0 ports (2 rear, 4 via header(s))
- 5 USB 3.0 ports (2 rear, 2 via header(s), 1 Type A)
|
Video Output |
|
Serial Port / Header |
- 2 COM Ports (1 rear, 1 header(s))
|
TPM |
|
|
 |
 |
PCI-E |
- 1 PCI-E 3.0 x8 (in x16 slot)
- 1 PCI-E 3.0 x8
- 1 PCI-E 3.0 x4 (in x8 slot)
|
M.2 |
- Interface: PCIe 3.0 x2
- Form Factor: 2280
|
|
 |
BIOS Type |
- 128Mb SPI Flash EEPROM with AMI BIOS
|
BIOS Features |
- Plug and Play (PnP)
- APM 1.2
- PCI 2.3
- DMI 2.3
- ACPI 1.0 / 2.0 / 3.0 / 4.0
- USB Keyboard support
- Hardware BIOS Virus protection
- SMBIOS 2.7.1
- UEFI 2.3.1
- RTC (Real Time Clock) Wakeup
|
|
 |
Software |
- Intel? Node Manager
- IPMI2.0
- NMI
- SPM
- SSM
- SUM
- SuperDoctor? 5
- Watchdog
|
Power Configurations |
- ACPI Power Management
- Power-on mode for AC power recovery
|
|
 |
Voltage |
- +12V, +3.3V, +5V, +5V standby, Chassis intrusion header, Monitors CPU voltages, Supports system management utility, System level control, VBAT
|
FAN |
- 5x 4-pin fan headers (up to 5 fans)
- Fan speed control
- Overheat LED indication
- Thermal control tachometer fan connectors
|
Temperature |
- PECI
- Thermal Monitor 2 (TM2) support
- Monitoring for CPU and chassis environment
- CPU thermal trip support
|
LED |
- CPU / System Overheat LED
- UID/Remote UID
|
Other Features |
- Control of power-on for recovery from AC power loss
- CPU thermal trip support for processor protection
- M.2 NGFF connector
- VHD
- WOL
|
|
 |
Operating Temperature Range |
- 0°C ~ 50°C (32°F ~ 122°F)
|
Non-Operating Temperature Range |
- -40°C - 70°C (-40°F - 158°F)
|
Operating Relative Humidity Range |
- 8% - 90% (non-condensing)
|
Non-Operating Relative Humidity Range |
- 5% - 95% (non-condensing)
|
|